<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Heat Trace Junction Box Kit | Junction Boxes</title>
	<atom:link href="https://traceheatingproducts.co.uk/product-category/junction-boxes/feed/" rel="self" type="application/rss+xml" />
	<link>https://traceheatingproducts.co.uk/product-category/junction-boxes/</link>
	<description>Supplier of Chromalox Trace Heating Products</description>
	<lastBuildDate>Tue, 02 Jun 2026 08:35:59 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.5</generator>

<image>
	<url>https://traceheatingproducts.co.uk/wp-content/uploads/2020/03/Favicon-150x150.png</url>
	<title>Heat Trace Junction Box Kit | Junction Boxes</title>
	<link>https://traceheatingproducts.co.uk/product-category/junction-boxes/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Junction Boxes for Self-Regulating Heating Cables  (3 and More Circuits)</title>
		<link>https://traceheatingproducts.co.uk/product/junction-boxes-for-self-regulating-heating-cables-3-and-more-circuits/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Tue, 02 Jun 2026 08:35:26 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/?post_type=product&#038;p=14153</guid>

					<description><![CDATA[<p>For installation onto a wall, onto a nearby metal structure or using a bracket directly onto the pipeline (brackets supplied separately).</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/junction-boxes-for-self-regulating-heating-cables-3-and-more-circuits/">Junction Boxes for Self-Regulating Heating Cables  (3 and More Circuits)</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Application</h2>
<p>Junction boxes for 3 and more self -regulating heating cables connection are designed for connection of self-regulating electrical heating cables to the bower network and for the branching of self-regulating heating cables. The box also supports branching of the power cable in utility networks.</p>
<h3>Accessories (to be ordered separately)</h3>
<p>Connection kit for self-regulating heating cables is specified depending on the type of cable used.</p>
<p>Brackets PB, KP, PL.JB0606 – for mounting the box onto the pipeline.</p>
<p>Z-profile – for mounting the box onto a metal structure or onto a wall.</p>
<p>Metal pipe strap PFS/3 – for mounting the bracket onto the pipeline.</p>
<h3>Technical Data</h3>
<p><strong>Dust and moisture protection rating &#8211;</strong> IP66<br />
<strong>Explosion protection marking &#8211;</strong> Ех еb IIC Т6&#8230;Т3 Gb, Ex tb IIIC T85°C…, T165°C Db<br />
<strong>Temperature group of the explosion hazard area &#8211;</strong> Т6<br />
<strong>Operating ambient temperature range &#8211; </strong>-60&#8230;+55 °С<br />
<strong>Operating voltage &#8211;</strong> max 550 V<br />
<strong>Operating current &#8211;</strong> max 50 A<br />
<strong>Enclosure dimensions &#8211;</strong> 160×160×94.5 mm<br />
<strong>Total weight (maximum) &#8211;</strong> 2.76 kg<br />
<strong>Material Box / Color &#8211;</strong> Glass fiber reinforced polyester / Black</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/junction-boxes-for-self-regulating-heating-cables-3-and-more-circuits/">Junction Boxes for Self-Regulating Heating Cables  (3 and More Circuits)</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Junction Boxes for Light Indication and Connection of Heating Cables to Power Supply</title>
		<link>https://traceheatingproducts.co.uk/product/junction-boxes-for-light-indication-and-connection-of-heating-cables-to-power-supply/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Mon, 11 May 2026 14:55:01 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/?post_type=product&#038;p=16800</guid>

					<description><![CDATA[<p>Junction boxes for light indication are designed to indicate the availability of power for heating sections based on self-regulating electric heating cables* and is intended for connecting heating cables to power network.</p>
<p>For installation onto a wall, onto a nearby metal structure or using a bracket directly onto the pipeline (brackets supplied separately).</p>
<p>Boxes JB2221-223 – allow connecting of one self-regulating heating cable to the power cable or two cables if the box is used for splicing.</p>
<p>Boxes JB2221-333 – allow connection to the power cable of up to three self-regulating heating cables with screw terminal straps and up to two – with push-in terminals.</p>
<p>The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability. Cable glands of the box are intended for connecting unarmored power cables with a diameter of 7 to 18 mm or armored power cables with a diameter of 12 to 20 mm.</p>
<p>The installed terminal blocks allow the connection of multi-core or single-core wires with a cross-section of 1.5 to 10 mm². Design options with screw or push-in terminals are available to order.</p>
<p>A light indicator with a super bright LED signals voltage at the heating section termination.</p>
<p>The green LED has a long service life and has a 180° angle view, including in direct sunlight.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/junction-boxes-for-light-indication-and-connection-of-heating-cables-to-power-supply/">Junction Boxes for Light Indication and Connection of Heating Cables to Power Supply</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h3>Accessories (to be ordered separately)</h3>
<p>Connection kit for self-regulating heating cables is specified depending on the type of cable used.</p>
<p>Brackets PB, KP, PL.JB0606 – for mounting the box onto the pipeline.</p>
<p>Z-profile – for mounting the box onto a metal structure or onto a wall.</p>
<p>Metal pipe strap PFS/3 – for mounting the bracket onto the pipeline.</p>
<p>Cable entry unit LEK/U – for penetrating of thermal insulation.</p>
<h3>Features</h3>
<ul>
<li>Provides light indication of power voltage presence at the end of heating cable section and connection of cables to power network</li>
<li>Compatible with all types of self-regulating electric heating cables</li>
<li>High mechanical strength</li>
<li>Critical component parts are included in the scope of supply. Metal pipe strap PFS/3, cable entry unit.</li>
<li>Wide application range</li>
<li>Quick and easy installation</li>
<li>High thermal stability</li>
<li>Non-corrosive</li>
<li>Approved for installation in explosion hazard areas</li>
</ul>
<h3>Technical Data</h3>
<p><strong>Dust and moisture protection rating &#8211;</strong> IP66<br />
<strong>Explosion protection marking &#8211;</strong> Ех db еb IIC Т6&#8230;Т3 Gb / Ex tb IIIC T85°C…T165°C Db<br />
<strong>Temperature group of the explosion hazard area &#8211;</strong> Т6<br />
<strong>Operating ambient temperature range &#8211; </strong> -60&#8230;+55 °С<br />
<strong>Operating voltage &#8211;</strong> max 550 V<br />
<strong>Operating current &#8211;</strong> max 50 A<br />
<strong>Electric life of the LED &#8211;</strong> &gt;10 hours<br />
<strong>LED power intake &#8211; </strong> &lt;1 W<br />
<strong>Light source &#8211;</strong> green LED<br />
<strong>View angle &#8211;</strong> 180°<br />
<strong>Enclosure dimensions JB2221-223 &#8211;</strong> 122×120×91.5 mm<br />
<strong>Enclosure dimensions JB2221-333 &#8211;</strong> 160×160×94.5 mm<br />
<strong>Total weight (maximum) JB2221-223 &#8211;</strong> 1.55 kg<br />
<strong>Total weight (maximum) JB2221-333 &#8211;</strong> 2.44 kg<br />
<strong>Material Box / Color</strong>  <strong>&#8211; </strong>Glass fiber reinforced polyester / Black</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/junction-boxes-for-light-indication-and-connection-of-heating-cables-to-power-supply/">Junction Boxes for Light Indication and Connection of Heating Cables to Power Supply</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Junction Boxes for Self-Regulating Heating Cables</title>
		<link>https://traceheatingproducts.co.uk/product/junction-boxes-for-self-regulating-heating-cables/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Sat, 02 May 2026 08:30:04 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/?post_type=product&#038;p=14140</guid>

					<description><![CDATA[<p>Designed for connecting self-regulating electric heating cables to the power network and for branching of self-regulating heating cables*.</p>
<p>For installation onto a wall, onto a nearby metal structure or using a bracket directly onto the pipeline (brackets supplied separately).</p>
<p>The enclosure design ensures moisture and dust ingress protection IP66 and high corrosion stability.</p>
<p>Cable gland of the box is intended for connecting unarmoured power cables with a diameter of 7 to 18 mm or armored power cables with a diameter of 12 to 20 mm.</p>
<p>The installed terminal blocks allow the connection of multi-core or single-core wires with a cross-section of 1.5 to 10 mm². Design options with screw or push-in terminals are available to order.</p>
<p><em>* This junction box is compatible with self-regulating heating cables</em></p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/junction-boxes-for-self-regulating-heating-cables/">Junction Boxes for Self-Regulating Heating Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Features</h2>
<ul>
<li>Efficient solution for power supply and input of self-regulating heating cables connection through thermal insulation in electric heating cable systems</li>
<li>Compatible with all types of self-regulating electric heating cables</li>
<li>Excludes the risk of damage to heating cables at connection points</li>
<li>Approved for installation in explosion hazard areas</li>
<li>Critical components are included in the scope of supply. Metal pipe strap PFS/3, cable entry unit and flexible sealed gland FSG to be ordered separately.</li>
<li>Wide application range</li>
<li>Quick and easy installation</li>
<li>High thermal stability</li>
<li>Non-corrosive</li>
</ul>
<h2>Application Areas</h2>
<p>The box allows connection of up to three self-regulating electric heating cables to the power cable and connection of up to three cables for branching.</p>
<h2>Technical Data</h2>
<p><strong>Dust and moisture protection rating &#8211;</strong> IP66<br />
<strong>Explosion protection marking &#8211;</strong> Ex eb IIC T6&#8230;T3 Gb, Ex tb IIIC T85°C&#8230;, T165°C Db<br />
<strong>Temperature group of the explosion hazard area &#8211;</strong> Т6<br />
<strong>Operating ambient temperature range -</strong> -60&#8230;+55 °С<br />
<strong>Operating voltage &#8211;</strong> max 550 V<br />
<strong>Operating current &#8211;</strong> max 50 A<br />
<strong>Enclosure dimensions JB 2221-223 &#8211;</strong> 122×120×91.5 mm<br />
<strong>Total weight (maximum) &#8211;</strong> 1.55 kg<br />
<strong>Material Box / Color- </strong> Glass fiber reinforced polyester / Black<br />
<strong>Material Pipe installation support / Color &#8211;</strong> Glass fiber reinforced polyester / Black</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/junction-boxes-for-self-regulating-heating-cables/">Junction Boxes for Self-Regulating Heating Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Junction Box</title>
		<link>https://traceheatingproducts.co.uk/product/junction-box/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Fri, 06 Dec 2019 22:23:23 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/?post_type=product&#038;p=700</guid>

					<description><![CDATA[<p>Features and Benefits<br />
• ABS enclosure<br />
• 125 mm x 125 mm x 75 mm<br />
• IP66 rated<br />
• Slotted DIN rail x 1<br />
• Terminal block rated to 16 A<br />
• 1 in 3 out</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/junction-box/">Junction Box</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>THP trace heating junction box measures 125 x 125 x 75mm and has ABS construction. The IP66 rated device provides superior safety and has terminal block rated for 16 A.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/junction-box/">Junction Box</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>U Series Long Line Heat Trace Connection Kits</title>
		<link>https://traceheatingproducts.co.uk/product/u-series-long-line-heat-trace-connection-kits/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Thu, 21 Nov 2019 17:08:41 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/u-series-long-line-heat-trace-connection-kits/</guid>

					<description><![CDATA[<p>UPC Power Connection Box NEMA 4X<br />
Entry for 1 Cable<br />
3/4” Conduit Hub Opening<br />
Lighted or Non-Lighted<br />
Use With: SRL, SRP, SRM/E, CWM, SRF, HWM<br />
Third-party certifications: UL Listed, CSA, FM, ATE</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/u-series-long-line-heat-trace-connection-kits/">U Series Long Line Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>NEMA 4X rated junction box designed to connect SRL, SRP, SRM/E and CWM cables to customer supplied power wiring. This kit provides water-resistant cable entry for one cable, enclosure support, terminal block, and a water-resistant corrosion-resistant wiring enclosure with a 3/4” opening to accept a conduit hub (CCH-2 or equal). A pipe strap (PS Series) is required to attach this model to a pipe. Small pipe adapter is available for pipe size less than 1-1/2”. Kit Dimensions: 9.78”H x 4.78”W x 3.6”D Kit Includes: 1 Junction box with DIN rail &amp; terminal block<br />
1 Compression fitting<br />
1 Locknut<br />
1 Silicone termination boot<br />
1 Pipe standoff<br />
1 O-ring<br />
1 Self-regulating cable grommet<br />
1 Constant wattage cable grommet</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/u-series-long-line-heat-trace-connection-kits/">U Series Long Line Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>U Series Long Line Heat Trace Connection Kits</title>
		<link>https://traceheatingproducts.co.uk/product/u-series-long-line-heat-trace-connection-kits-2/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Thu, 21 Nov 2019 17:08:41 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/u-series-long-line-heat-trace-connection-kits-2/</guid>

					<description><![CDATA[<p>UMC Power Connection Box NEMA 4X<br />
Entry for 1 Cable<br />
3/4” Conduit Hub Opening<br />
Lighted or Non-Lighted<br />
Use With: SRL, SRP, SRM/E, CWM, SRF, HWM<br />
Third-party certifications: UL Listed, CSA, FM, ATE</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/u-series-long-line-heat-trace-connection-kits-2/">U Series Long Line Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>NEMA 4X rated junction box designed to connect SRL, SRP, SRM/E and CWM cables to customer supplied power wiring. This kit provides water-resistant cable entry for one cable, enclosure support, terminal block, and a water-resistant corrosion-resistant wiring enclosure with a 3/4” opening to accept a conduit hub (CCH-2 or equal). A pipe strap (PS Series) is required to attach this model to a pipe. Small pipe adapter is available for pipe size less than 1-1/2”. Kit Dimensions: 9.78&#8243;H x 8.69&#8243;W x 3.6&#8243;D Kit Includes: 1 Junction box with DIN rail &amp; terminal block<br />
1 Compression fitting<br />
1 Locknut<br />
3 Silicone termination boot<br />
1 Pipe standoff<br />
1 O-ring<br />
1 Self-regulating cable grommet<br />
1 Constant wattage cable grommet</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/u-series-long-line-heat-trace-connection-kits-2/">U Series Long Line Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>U Series Heat Trace Connection Kits</title>
		<link>https://traceheatingproducts.co.uk/product/u-series-heat-trace-connection-kits-2/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Thu, 21 Nov 2019 17:08:41 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/u-series-heat-trace-connection-kits-2/</guid>

					<description><![CDATA[<p>UPC Long Line Power Connection Kit NEMA 4X<br />
Entry for 1 Cable<br />
3/4” Conduit Hub Opening<br />
Mounts Above Insulation for Easy Access<br />
CSA Approved:<br />
• Class I, Div. 2 Groups B, C, D<br />
(gases, vapors)<br />
• Class II, Div. 2 Groups E, F, G<br />
(combustible dust)<br />
• Class III (easily ignitable fibers and fillings)<br />
• Temperature Coded per Design. Contact Chromalox Sales</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/u-series-heat-trace-connection-kits-2/">U Series Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>NEMA 4X rated junction box designed to connect SLL heating cables to customer supplied power wiring. This kit provides water-resistant cable entry for one cable, enclosure support, crimp connections, cold leads, and a water-resistant corrosion- resistant wiring enclosure with an opening to accept a 3/4&#8243; conduit hub. A pipe strap (PS series) is required to attach this model to a pipe. Kit Dimensions: 9.78&#8243;H x 8.69&#8243;W x 3.6&#8243;0 Kit Includes: 1 &#8211; Junction Box<br />
1 &#8211; Pipe Standoff<br />
1 &#8211; Locknut<br />
1 &#8211; Compression Fitting<br />
1 &#8211; 0-Ring<br />
1 &#8211; Grommet<br />
6 &#8211; Cold Leads (12 AWG &amp; 4 AWG)<br />
9 &#8211; Crimps<br />
4 &#8211; Tape Strips<br />
2 &#8211; Solder</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/u-series-heat-trace-connection-kits-2/">U Series Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>U Series Heat Trace Connection Kits</title>
		<link>https://traceheatingproducts.co.uk/product/u-series-heat-trace-connection-kits-3/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Thu, 21 Nov 2019 17:08:41 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/u-series-heat-trace-connection-kits-3/</guid>

					<description><![CDATA[<p>UMC Long Line Power Connection Kit NEMA 4X<br />
Entry for 1 Cable<br />
3/4” Conduit Hub Opening<br />
Mounts Above Insulation for Easy Access<br />
CSA Approved:<br />
• Class I, Div. 2 Groups B, C, D<br />
(gases, vapors)<br />
• Class II, Div. 2 Groups E, F, G<br />
(combustible dust)<br />
• Class III (easily ignitable fibers and fillings)<br />
• Temperature Coded per Design. Contact Chromalox Sales</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/u-series-heat-trace-connection-kits-3/">U Series Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>NEMA 4X rated junction box designed to connect two SLL heating cables to each other This kit provides water-resistant cable entry for one cable, enclosure support, crimp connections, and a waterresistant corrosion-resistant wiring enclosure with an opening to accept a 3/4&#8243; conduit hub. A pipe strap (PS series) is required to attach this model to a pipe. Kit Dimensions: 9.78&#8243;H x 8.69&#8243;W x 3.6&#8243;0 Kit Includes 1 &#8211; Junction Box<br />
1 &#8211; Pipe Standoff<br />
1 &#8211; Locknut<br />
1 &#8211; Compression Fitting<br />
1 &#8211; 0-Ring<br />
1 &#8211; Grommet<br />
1 &#8211; Brass Locknut<br />
1 &#8211; Conduit Plug<br />
9 &#8211; Crimps<br />
4 &#8211; Tape Strips<br />
2 &#8211; Solder</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/u-series-heat-trace-connection-kits-3/">U Series Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DL Series Heat Trace Connection Kits</title>
		<link>https://traceheatingproducts.co.uk/product/dl-series-heat-trace-connection-kits-2/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Thu, 21 Nov 2019 17:08:41 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/dl-series-heat-trace-connection-kits-2/</guid>

					<description><![CDATA[<p>RTPC Power Connection Kit Use with: SRL, SRP, SRM/E, CWM, SRF<br />
NEMA 4X Enclosures<br />
Cable Entry Up to 3 Cables<br />
3/4" Conduit Hub Opening<br />
Stainless Steel Hardware<br />
Corrosion &#38; Weather Resistant Ryton® Construction<br />
Third-party certifications: UL Listed, CSA, FM</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/dl-series-heat-trace-connection-kits-2/">DL Series Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>RTPC Power Connection Box is a NEMA 4X rated junction box designed to connect all Chromalox Rapid Trace Heating Cables to customer supplied power wiring. This kit provides waterproof cable entry for up to three cables, enclosure support, terminal block and a waterproof, corrosion resistant wiring enclosure with an opening to accept a 3/4&#8243; conduit hub (Chromalox CCH-2 or equal). A pipe strap (Chromalox PS or equal) is required to attach this model to a pipe. RTPC — Power Connection Kit 1 molded junction box consisting of:<br />
1 base<br />
1 box w/conduit opening<br />
1 lid<br />
1 three position terminal block<br />
1 mounting screw for terminal block<br />
1 GRSR self-regulating cable sealing grommet<br />
1 GRCW constant wattage sealing grommet</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/dl-series-heat-trace-connection-kits-2/">DL Series Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DL Series Heat Trace Connection Kits</title>
		<link>https://traceheatingproducts.co.uk/product/dl-series-heat-trace-connection-kits-3/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Thu, 21 Nov 2019 17:08:41 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/dl-series-heat-trace-connection-kits-3/</guid>

					<description><![CDATA[<p>RTST Splice &#38; Tee Kit Use With: SRL, SRP, SRM/E, CWM, SRF<br />
NEMA 4X Enclosure<br />
Cable Entry Up to 3 Cables<br />
Straight or Tee Connections<br />
Stainless Steel Hardware<br />
Corrosion &#38; Weather Resistant Ryton® Construction<br />
Third-party certifications: UL Listed, CSA, FM</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/dl-series-heat-trace-connection-kits-3/">DL Series Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>RTST Splice &amp; Tee Box is a NEMA 4X rated junction box designed to make straight or tee splices for all Chromalox Rapid Trace Heating Cables. This model provides waterproof cable entry (for two cables for a splice or three cables for a tee), enclosure support, terminal block and a waterproof, corrosion resistant wiring enclosure. A pipe strap (Chromalox PS or equal) is required to attach this model to a pipe. RTST — Splice &amp; Tee Kit 1 molded junction box consisting of:<br />
1 base<br />
1 box<br />
1 lid<br />
1 three position terminal block<br />
1 mounting screw for terminal block<br />
3 GRSR Self-regulating cable sealing grommet<br />
3 GRCW Constant wattage sealing grommets RTST-SL — Splice &amp; Tee Kit w/Signal Light (Ordinary Area Only) 1 molded junction box consisting of:<br />
1 base<br />
1 box<br />
1 lid w/signal light installed (LED style) Specify: SL1 for 120 Volt, SL2 for 208-240 Volt, SL3 for 277 Volt operation<br />
1 three position terminal block<br />
1 mounting screw for terminal block<br />
1 GRSR Self-regulating cable sealing grommet<br />
1 GRCW Constant wattage sealing grommet</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/dl-series-heat-trace-connection-kits-3/">DL Series Heat Trace Connection Kits</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
