<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Thermostats Supplied and Delivered by Trace Heating Products</title>
	<atom:link href="https://traceheatingproducts.co.uk/product-category/thermostats/feed/" rel="self" type="application/rss+xml" />
	<link>https://traceheatingproducts.co.uk/product-category/thermostats/</link>
	<description>Supplier of Chromalox Trace Heating Products</description>
	<lastBuildDate>Sat, 16 Mar 2024 12:55:53 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>

<image>
	<url>https://traceheatingproducts.co.uk/wp-content/uploads/2020/03/Favicon-150x150.png</url>
	<title>Thermostats Supplied and Delivered by Trace Heating Products</title>
	<link>https://traceheatingproducts.co.uk/product-category/thermostats/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Thermostats</title>
		<link>https://traceheatingproducts.co.uk/product/thermostats-10/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Mon, 09 Dec 2019 12:15:31 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/?post_type=product&#038;p=720</guid>

					<description><![CDATA[<p>THR Heat Trace / Freeze Protection Thermostats - THR Remote Mount for Heat Trace (Bulb &#38; Capillary)<br />
22 Amp Resistive Switch<br />
Single and Dual Output Models<br />
± 1% Setpoint Repeatability<br />
Fast Response for Protection of Valves and Piping<br />
NEMA 4X, 7 and 9 Enclosures<br />
Third-party certifications: UL Listed, CSA, ATEX</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-10/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>THR: NEMA 4X Line or Pipe Sensing<br />
Maintaining proper viscosity and flow is critical in heat trace or freeze protection applications. The THR remote mount thermostats utilize a stainless steel bulb and capillary design to accurately sense temperature at key points along a pipe. The THL direct mount thermostats feature liquid-filled thermal assemblies and sense air temperatures from 15 to 140˚F. Both models are epoxy coated to seal from moisture and contaminants in compliance with NEMA 4X requirements. NEMA 7 stats TXR and TXL are designed for Class I, Division I and 2, Groups B, C, D, and Class 2, Division I and 2, Group E, F, G.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-10/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermostats</title>
		<link>https://traceheatingproducts.co.uk/product/thermostats-9/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Mon, 09 Dec 2019 12:08:40 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/?post_type=product&#038;p=718</guid>

					<description><![CDATA[<p>THL Heat Trace / Freeze Protection Thermostats - THL Direct Mount for Freeze Protection (Ambient)<br />
22 Amp Resistive Switch<br />
Single and Dual Output Models<br />
± 1% Setpoint Repeatability<br />
Fast Response for Protection of Valves and Piping<br />
NEMA 4X, 7 and 9 Enclosures<br />
Third-party certifications: UL Listed, CSA, ATEX</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-9/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>THL: NEMA 4X Ambient Air Sensing Maintaining proper viscosity and flow is critical in heat trace or freeze protection applications. The THR remote mount thermostats utilize a stainless steel bulb and capillary design to accurately sense temperature at key points along a pipe. The THL direct mount thermostats feature liquid-filled thermal assemblies and sense air temperatures from 15 to 140˚F. Both models are epoxy coated to seal from moisture and contaminants in compliance with NEMA 4X requirements. NEMA 7 stats TXR and TXL are designed for Class I, Division I and 2, Groups B, C, D, and Class 2, Division I and 2, Group E, F, G.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-9/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermostats</title>
		<link>https://traceheatingproducts.co.uk/product/thermostats-8/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Mon, 09 Dec 2019 11:53:56 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/?post_type=product&#038;p=717</guid>

					<description><![CDATA[<p>RTAS &#38; RTAS-EP Ambient Sensing Integrated Temperature Controls Line or Ambient Sensing Thermostats<br />
ElectroMechanical Control<br />
Rugged, Corrosion Resistant Construction<br />
NEMA 4X Design with Corrosion and Weather Resistant Ryton® Construction<br />
Ambient Sensing:<br />
- 120 - 480 Vac<br />
- 0 - 225°F Temp. Rating<br />
- 9/16"" OD x 4"" SS Probe<br />
- Ordinary &#38; Hazardous Area (Div. 2) Approvals<br />
Bulb &#38; Capillary:<br />
- 120 - 480 Vac<br />
- 0 - 400°F Setpoint Range<br />
- 1/4"" OD x 7-1/4"" SS Bulb and 3 Ft. Capillary<br />
- Ordinary &#38; Hazardous Area (Div. 2) Approvals<br />
UL, CSA, and FM Approved</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-8/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>RTAS is an ambient-sensing thermostat which is generally used for freeze protection in ordinary (non-hazardous) areas. The thermostat is mounted through the end of the oblique sided enclosure lid. In fact, because there is so much room in this model, multiple heating cables can be terminated. The stainless steel sheathed, inverted bellows probe provides good sensitivity, resulting in more accurate control. RTAS-EP is a modified version of the RTAS which utilizes a hermetically sealed switch. Since this switch has no arcing contacts, it can be used in Division 2 Hazardous Areas.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-8/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermostats</title>
		<link>https://traceheatingproducts.co.uk/product/thermostats-7/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Mon, 09 Dec 2019 11:47:18 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/?post_type=product&#038;p=715</guid>

					<description><![CDATA[<p>RTAS &#38; RTAS-EP Ambient Sensing Integrated Temperature Controls Line or Ambient Sensing Thermostats<br />
ElectroMechanical Control<br />
Rugged, Corrosion Resistant Construction<br />
NEMA 4X Design with Corrosion and Weather Resistant Ryton® Construction<br />
Ambient Sensing:<br />
- 120 - 480 Vac<br />
- 0 - 225°F Temp. Rating<br />
- 9/16"" OD x 4"" SS Probe<br />
- Ordinary &#38; Hazardous Area (Div. 2) Approvals<br />
Bulb &#38; Capillary:<br />
- 120 - 480 Vac<br />
- 0 - 400°F Setpoint Range<br />
- 1/4"" OD x 7-1/4"" SS Bulb and 3 Ft. Capillary<br />
- Ordinary &#38; Hazardous Area (Div. 2) Approvals<br />
UL, CSA, and FM Approved</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-7/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>RTAS is an ambient-sensing thermostat which is generally used for freeze protection in ordinary (non-hazardous) areas. The thermostat is mounted through the end of the oblique sided enclosure lid. In fact, because there is so much room in this model, multiple heating cables can be terminated. The stainless steel sheathed, inverted bellows probe provides good sensitivity, resulting in more accurate control. RTAS-EP is a modified version of the RTAS which utilizes a hermetically sealed switch. Since this switch has no arcing contacts, it can be used in Division 2 Hazardous Areas.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-7/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermostats</title>
		<link>https://traceheatingproducts.co.uk/product/thermostats-6/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Mon, 09 Dec 2019 11:43:26 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/?post_type=product&#038;p=711</guid>

					<description><![CDATA[<p>PIT Non-Indicating Temperature Controllers Compact Size<br />
Explosion Resistant and Raintight Applications<br />
0 - 150°F and 100 - 250°F Temperature Range<br />
Single Phase, 120 - 277 Vac<br />
Bulb &#38; Capillary<br />
UL Listed</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-6/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>For a variety of process applications requiring rain-tight or explosion-resistant enclosure, PIT controllers may be used in pipe tracing and snow melting applications with electric heating cable.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-6/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermostats</title>
		<link>https://traceheatingproducts.co.uk/product/thermostats-5/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Mon, 09 Dec 2019 11:36:48 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/?post_type=product&#038;p=706</guid>

					<description><![CDATA[<p>Maintaining proper viscosity and flow is critical in heat trace or freeze protection applications. The E100 remote mount thermostats utilize a stainless steel bulb and capillary design to accurately sense temperature at key points along a pipe. The B100 direct mount thermostats feature liquid-filled thermal assemblies and sense air temperatures from 15 to 140°F. Both models are epoxy coated to seal from moisture and contaminants in compliance with NEMA 4X requirements. NEMA 7 stats E121/122/122P and B121 are designed for Class I, Division I and 2, Groups B, C, D, and Class 2, Division I and 2, Group E, F, G. Product Specifications many be found in the catalog page. WARNING: Hazard of Fire. These devices function as temperature controls only. Because they do not fail-safe, an approved temperature and/or pressure safety control must be used for safe operation.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-5/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&#8220;B100 &amp; E100 Heat Trace/ Freeze Protection Thermostats B100 Direct Mount for Freeze Protection (Ambient)<br />
E100 Remote Mount for Heat Trace (Bulb &amp; Capillary)<br />
22 Amp Resistive Switch<br />
Single and Dual Output Models<br />
±1% Setpoint Repeatability<br />
Fast Response for Protection of Valves and Piping<br />
NEMA 4X, 7 and 9 Enclosures<br />
Third-party certifications: UL Listed, CSA, FM (models E121/122, B121 only) &#8220;</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-5/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermostats</title>
		<link>https://traceheatingproducts.co.uk/product/thermostats/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Fri, 01 Nov 2019 10:17:46 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/thermostats/</guid>

					<description><![CDATA[<p>TXR: NEMA 7 Line or Pipe Sensing Maintaining proper viscosity and flow is critical in heat trace or freeze protection applications. The THR remote mount thermostats utilize a stainless steel bulb and capillary design to accurately sense temperature at key points along a pipe. The THL direct mount thermostats feature liquid-filled thermal assemblies and sense air temperatures from 15 to 140˚F. Both models are epoxy coated to seal from moisture and contaminants in compliance with NEMA 4X requirements. NEMA 7 stats TXR and TXL are designed for Class I, Division I and 2, Groups B, C, D, and Class 2, Division I and 2, Group E, F, G.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>TXR Heat Trace / Freeze Protection Thermostats &#8211; TXR Remote Mount for Heat Trace (Bulb &amp; Capillary)<br />
22 Amp Resistive Switch<br />
Single and Dual Output Models<br />
± 1% Setpoint Repeatability<br />
Fast Response for Protection of Valves and Piping<br />
NEMA 4X, 7 and 9 Enclosures<br />
Third-party certifications: UL Listed, CSA, ATEX, FM</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermostats</title>
		<link>https://traceheatingproducts.co.uk/product/thermostats-2/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Fri, 01 Nov 2019 10:17:46 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/thermostats-2/</guid>

					<description><![CDATA[<p>TXL: NEMA 7 Ambient Air Sensing Maintaining proper viscosity and flow is critical in heat trace or freeze protection applications. The THR remote mount thermostats utilize a stainless steel bulb and capillary design to accurately sense temperature at key points along a pipe. The THL direct mount thermostats feature liquid-filled thermal assemblies and sense air temperatures from 15 to 140˚F. Both models are epoxy coated to seal from moisture and contaminants in compliance with NEMA 4X requirements. NEMA 7 stats TXR and TXL are designed for Class I, Division I and 2, Groups B, C, D, and Class 2, Division I and 2, Group E, F, G.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-2/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>TXL Heat Trace / Freeze Protection Thermostats &#8211; TXR Remote Mount for Heat Trace (Bulb &amp; Capillary)<br />
22 Amp Resistive Switch<br />
Single and Dual Output Models<br />
± 1% Setpoint Repeatability<br />
Fast Response for Protection of Valves and Piping<br />
NEMA 4X, 7 and 9 Enclosures<br />
Third-party certifications: UL Listed, CSA, ATEX, FM</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-2/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermostats</title>
		<link>https://traceheatingproducts.co.uk/product/thermostats-3/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Fri, 01 Nov 2019 10:17:46 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/thermostats-3/</guid>

					<description><![CDATA[<p>The DTS-HAZ digital thermostat is a microprocessor based temperature control and power connection kit. It is used for freeze protection or process temperature maintenance of pipes or tanks protected by heat tracing products. This thermostat can be used with Constant Wattage, Mineral Insulated or Self-Regulating heating cables in Ordinary area or Class 1, Division 2 and IECEx/ATEX Zone II hazardous area locations. This unit is designed to provide local temperature control and monitoring for heat traced pipes or tanks across a variety of industries and applications and will switch 30 amperes of current The DTS-HAZ provides easy programming of the temperature set point, high and low temperature alarms, the deadband, the temperature units, the soft start function and the alarm state through the front panel push buttons. LED lights are provided for indication of power to the unit, heater power on (load) and alarm status. A Fail Safe solid state alarm is included for wiring to your building management system to indicate alarm status. This alarm may be set to open or close on all alarm conditions including loss of power, high or low temperature alarm and RTD failure. The loss of power indication qualifies this unit to be used to sense temperature and control heat trace when used in fire protection systems. Choose either the DC or the AC customer supplied voltage alarm variation. The minimum operating ambient temperature is -40°F (-40°C). This unit has programmable high and low temperature alarm set points from -80°F (-62°C) to 1150°F (621°C).<br />
The DTS-HAZ employs a Soft Start feature that uses a proprietary software algorithm which eliminates the inherent self-regulating in-rush current, resulting in less nuisance tripping at cold temperatures. For added flexibility, the user may disable the soft start feature for nonheat trace applications. The alarm contact may be either normally open or normally closed.<br />
A 100 Ohm platinum RTD is provided with a 3 foot (1 M) lead resulting in flexible mounting options for the user.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-3/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>DTS-HAZ Heat Trace Digital Thermostat 30 Amp Solid State Relay (SSR) Output<br />
120 to 277 Vac Operation<br />
C1D2 Hazardous Area Approval<br />
ATEX / IECEx Zone II<br />
On/Off Control With 100 Degree Deadband Programmable In One Degree Increments<br />
Selectable Soft-Start Feature – Eliminates SR Cable In-Rush<br />
LED Indication for Power, Alarm and Load<br />
Large LED Display of Process Variables<br />
Programmable High &amp; Low Temperature Alarms<br />
Solid State Alarm for Remote Indication of Alarm Status:<br />
&#8211; AC Alarm: DTS-HAZ<br />
&#8211; DC Alarm: DTS-HAZ-DC<br />
NEMA 4X Enclosure<br />
Integral Pipe Stand<br />
Optional Wall Mount<br />
100 Ohm Platinum RTD &#8211; Included<br />
Enclosure Serves as Heating Cable, A/C Power &amp; Sensor Connection<br />
Works with SR, CWM and MI Cable<br />
RoHS Compliant<br />
UL, cUL Listed, CE Approved</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-3/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Thermostats</title>
		<link>https://traceheatingproducts.co.uk/product/thermostats-4/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Fri, 01 Nov 2019 10:17:46 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/thermostats-4/</guid>

					<description><![CDATA[<p>TraceStat: 110V and 230V AC power, with volt-free contacts for low temperature and loss of power.For line sensing or ambient air sensing trace heating applications, the TraceStat thermostats are the industry ideal. They accommodate direct termination of as many as three trace heating cables, negating the need for installation of additional termination devices. Furthermore, with full 20 Amp rating, IP65 ingress protection, tamper-proof settings and no calibration or preventative maintenance required, you can leave them to get on with their job! The bright digital display indicates the sensed temperature, while all operating parameters are factory set and stored in the configurable set-up system, keeping your settings safe from accidental change. The TraceStats can be surface-mounted directly or pipe-mounted via a dual leg bracket. Each unit comes with 1.8m of sensor cable as standard so the TraceStats can, if preferred, be sited away from the sensing point, eg sensor on outside piping, TraceStat located in your Plant Room. The TraceStat15 is fitted with a volt-free contact output for remote indication of loss of power to traceheating. The TraceStatZ11 can have a further similar output to indicate low temperature.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-4/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Fit and forget design □ LED temperature display<br />
□ 20 Amp rating<br />
□ 110V or 230V AC power<br />
□ Connects up to three trace heating radials<br />
□ IP65<br />
□ Loss of power volt-free contact output<br />
□ Pipe sensing or ambient air sensing models<br />
□ 1.8m remote sensor as standard<br />
□ Remote sensing up to 45m</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/thermostats-4/">Thermostats</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
