<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Heat Trace Cable | Trace Heating Cable | Heating Trace Cable</title>
	<atom:link href="https://traceheatingproducts.co.uk/product-category/heat-trace-cables/feed/" rel="self" type="application/rss+xml" />
	<link>https://traceheatingproducts.co.uk/product-category/heat-trace-cables/</link>
	<description>Supplier of Chromalox Trace Heating Products</description>
	<lastBuildDate>Sat, 16 Mar 2024 12:57:03 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>

<image>
	<url>https://traceheatingproducts.co.uk/wp-content/uploads/2020/03/Favicon-150x150.png</url>
	<title>Heat Trace Cable | Trace Heating Cable | Heating Trace Cable</title>
	<link>https://traceheatingproducts.co.uk/product-category/heat-trace-cables/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Self Regulating Heat Trace Cables</title>
		<link>https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Fri, 01 Nov 2019 10:17:46 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables/</guid>

					<description><![CDATA[<p>SRL - 2CR Self Regulating Heating Cable, braid and polyolefin over jacket, Available in 10 W/m , 16 W/m , 24 W/w , 30 W/m @ 10°C. For frost protection up to 65°C, 240V &#38; 110V, ATEX T5</p>
<p>Self-Regulating Low Temperature<br />
• Self-Regulating, Energy Efficient<br />
• 16 AWG Buss Wire<br />
• Circuit Lengths to 660 Feet<br />
• Process Temperature Maintenance to 150°F (65°C)<br />
• Maximum Continuous Exposure Temperature, Power Off, 185°F (85°C)<br />
• Industrial Freeze Protection Applications<br />
• Single or Dual Monitor Wires Available<br />
• Field Splicing Without Disrupting Heat Output<br />
• 3, 5, 8 and 10 W/Ft.<br />
• 120 and 208 - 277 Volt From Stock<br />
• Approximate Size .47 in. W x .20 in.H<br />
• Min. Bend Radius 1-1/8 in.<br />
• For Use on Metal and Plastic Pipes &#38; Tanks<br />
• Factory Mutual (FM) Approved, UL Listed, and CSA certified for ordinary areas. UL Listed for freeze protection of fire protection system piping.<br />
• ATEX, IECEx, FM, and CSA Approved for hazardous (classified) areas when used with U Series, HL, DL, and EL accessories.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Chromalox SRL self-regulating heating cable provides safe, reliable heat tracing for freeze protection of pipes, valves, tanks and similar applications. Constructed of industrial grade 16 AWG buss wire with a tinned copper braid and optional overjacketing, SRL ensures operating integrity in Div. 2 hazardous environments as well as certain corrosive industrial environments. SRL heating cable has a maximum maintenance temperature rating of 150°F (65°C). WARNING — A ground fault protection device is required by NEC to minimize the danger of fire if the heating cable is damaged or improperly installed. A minimum trip level of 30mA is recommended to minimize nuisance tripping. Features<br />
Energy efficient, self-regulating SRL uses less energy when less heat is required.<br />
Easy to install, SRL can be cut to any length (up to max. circuit length) in the field.<br />
Field splices can be performed easily in minutes with no scrap or wasted cold sections.<br />
SRL features lower installed cost than steam tracing, less maintenance expense and less downtime.<br />
SRL can be single overlapped without burnout, which simplifies heat tracing of in-line process equipment such as valves, elbows and pumps.<br />
Because SRL is self-regulating, over-temperature conditions are minimized.<br />
Chromalox termination, splice, tee and end seal kits reduce installation time.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Self Regulating Heat Trace Cables</title>
		<link>https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-2/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Fri, 01 Nov 2019 10:17:46 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-2/</guid>

					<description><![CDATA[<p>SRL - 2CT Self Regulating Heating Cable, braid and fluoropolymer over jacket, Available in 10 W/m , 16 W/m , 24 W/m , 30 W/m @ 10°C. For frost protection up to 65°C, 240V &#38; 110V, ATEX T5</p>
<p>Self-Regulating Low Temperature<br />
• Self-Regulating, Energy Efficient<br />
• 16 AWG Buss Wire<br />
• Circuit Lengths to 660 Feet<br />
• Process Temperature Maintenance to 150°F (65°C)<br />
• Maximum Continuous Exposure Temperature, Power Off, 185°F (85°C)<br />
• Industrial Freeze Protection Applications<br />
• Single or Dual Monitor Wires Available<br />
• Field Splicing Without Disrupting Heat Output<br />
• 3, 5, 8 and 10 W/Ft.<br />
• 120 and 208 - 277 Volt From Stock<br />
• Approximate Size .47 in. W x .20 in.H<br />
• Min. Bend Radius 1-1/8 in.<br />
• For Use on Metal and Plastic Pipes &#38; Tanks<br />
• Factory Mutual (FM) Approved, UL Listed, and CSA certified for ordinary areas. UL Listed for freeze protection of fire protection system piping.<br />
• ATEX, IECEx, FM, and CSA Approved for hazardous (classified) areas when used with U Series, HL, DL, and EL accessories.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-2/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Chromalox SRL self-regulating heating cable provides safe, reliable heat tracing for freeze protection of pipes, valves, tanks and similar applications. Constructed of industrial grade 16 AWG buss wire with a tinned copper braid and optional overjacketing, SRL ensures operating integrity in Div. 2 hazardous environments as well as certain corrosive industrial environments. SRL heating cable has a maximum maintenance temperature rating of 150°F (65°C). WARNING — A ground fault protection device is required by NEC to minimize the danger of fire if the heating cable is damaged or improperly installed. A minimum trip level of 30mA is recommended to minimize nuisance tripping. Features<br />
Energy efficient, self-regulating SRL uses less energy when less heat is required.<br />
Easy to install, SRL can be cut to any length (up to max. circuit length) in the field.<br />
Field splices can be performed easily in minutes with no scrap or wasted cold sections.<br />
SRL features lower installed cost than steam tracing, less maintenance expense and less downtime.<br />
SRL can be single overlapped without burnout, which simplifies heat tracing of in-line process equipment such as valves, elbows and pumps.<br />
Because SRL is self-regulating, over-temperature conditions are minimized.<br />
Chromalox termination, splice, tee and end seal kits reduce installation time.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-2/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Self Regulating Heat Trace Cables</title>
		<link>https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-3/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Fri, 01 Nov 2019 10:17:46 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-3/</guid>

					<description><![CDATA[<p>Self Regulating Heating Cable, braid and fluoropolymer overjacket, Available in 16 W/m , 30 W/m , 50 W/m @ 10°C. For<br />
process temperature maintenance up to 110°C and frost protection for pipes with high heat losses, 240V &#38; 110V, ATEX T4 SRP<br />
Self-Regulating Process Temperature<br />
Self- Regulating, Energy Efficient<br />
16 AWG Buss Wire<br />
Circuit Lengths to 750 ft.<br />
Process Temperature Maintenance to 230°F (110°C)<br />
Maximum Continuous Exposure Temperature, Power Off, 275°F (135°C)<br />
Available in 5, 10, and 15 Watts per Foot<br />
120 and 208-277 Volts Available from Stock<br />
Industrial Process Maintenance Applications<br />
Approximate Size .47 in. W x .20 in. H<br />
Min. Bend Radius 1-1/8 in.<br />
For use on Metallic Pipes<br />
Consult Factory for use on Plastic Piping<br />
Factory Mutual (FM) approved for ordinary areas.<br />
FM, ATEX and IECEx approved for hazardous (classified) areas when used with U Series and DL accessories.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-3/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Chromalox SRP self-regulating heating cable provides safe, reliable heat tracing for process maintenance applications to 230°F (110°C) or freeze protection of pipes / tank with high heat losses. Constructed of industrial grade 16 AWG buss wire with a tinned copper braid and optional over jacketing, SRP ensures operating integrity most hostile industrial environments. WARNING — A ground fault protection device is required by NEC to minimize the danger of fire if the heating cable is damaged or improperly installed. A minimum trip level of 30mA is recommended to minimize nuisance tripping. Features<br />
• Energy efficient, self-regulating SRP uses less energy when less heat is required.<br />
• Easy to install, SRP can be cut to any length (up to max circuit length) in the field.<br />
• SRP features lower installed cost than steam tracing, less maintenance expense and less down time.<br />
• SRP can be single overlapped without burnout, which simplifies heat tracing of in-line process equipment such as valves, elbows and pumps.<br />
• Because SRP is self-regulating, over-temperature conditions are minimized.<br />
• Chromalox U-Series Connection Kits reduce installation time. Approvals<br />
Factory Mutual (FM) approved for ordinary areas. FM approved for hazardous (classified) areas when used with U Series and DL accessories. FM Approval:<br />
• Class I, Division 2, Groups B, C, D (Gases, vapours)<br />
• Class II, Divisions 1*&amp;2, Groups F, G (Combustible dust)<br />
• Class III, Division 2 (Easily ignitable fibres and fillings)<br />
• Class I, Zone 1, AEx e II<br />
• 3,5,8 and 10 Watt Rated T4 Temperature Class</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-3/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Self Regulating Heat Trace Cables</title>
		<link>https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-4/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Fri, 01 Nov 2019 10:17:46 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-4/</guid>

					<description><![CDATA[<p>Self Regulating Heating Cable, braid and fluoropolymer overjacket,Available in 10 W/m , 16 W/m , 24 W/m , 45 W/m , 60 W/m @ 10°C. For<br />
process temperature maintenance up to 150°C and frost protection for pipes that are steam cleaned, 240V &#38; 110V , ATEX T3 SRME<br />
Self-Regulating Medium Temperature<br />
Self-Regulating, Energy Efficient<br />
16 AWG Buss Wire<br />
Process Temperature Maintenance to 302°F (150°C)<br />
Maximum Continuous Exposure Temperature, Power Off, 420°F (215°C)<br />
Industrial Process Maintenance Applications<br />
Industrial Freeze Protection Applications<br />
Single or Dual Monitor Wires Available<br />
Steam Cleanable on Process Equipment Up to 300 PSIG<br />
5, 8, 10, 15 and 20 W/Ft.<br />
120 and 208 - 277 Volt From Stock<br />
Approximate Size .47 in. W x .20 in. H<br />
Minimum Bend Radius 1-1/8 in.<br />
For Use on Metallic Pipes Only<br />
Factory Mutual (FM) Approved, UL Listed, and CSA certified for ordinary areas.<br />
UL Listed for freeze protection of fire protection system piping.<br />
ATEX, IECEx, FM, and CSA Approved for hazardous (classified) areas when used with U Series, HL, DL, and EL accessories.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-4/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Chromalox SRM/E self-regulating heating cable provides safe, reliable heat tracing for process temperature maintenance and freeze protection of pipes, valves, tanks and similar applications. Constructed of industrial grade 16 AWG buss wire with metal braid and optional overjacketing, SRM/E ensures operating integrity in most hostile industrial environments. The 420°F (215°C) maximum exposure temperature rating allows steam cleaning of process equipment with up to 300 psig steam. WARNING — A ground fault protection device is required by NEC to minimize the danger of fire if the heating cable is damaged or improperly installed. A minimum trip level of 30mA is recommended to minimize nuisance tripping. Features<br />
• Energy efficient, self-regulating SRM/E uses less energy when less heat is required.<br />
• Easy to install, SRM/E can be cut to any length (up to max. circuit length) in the field.<br />
• Field splices can be performed easily in minutes with no scrap or wasted cold sections.<br />
• With lower installed cost than steam tracing, SRM/E features less maintenance expense and downtime.<br />
• SRM/E can be overlapped without burnout, which simplifies heat tracing of in-line process equipment such as valves, elbows and pumps.<br />
• Because SRM/E is self-regulating, overtemperature conditions are minimized.<br />
• Chromalox termination, splice, tee and end seal kits reduce installation time.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-4/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Self Regulating Heat Trace Cables</title>
		<link>https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-5/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Fri, 01 Nov 2019 10:17:46 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-5/</guid>

					<description><![CDATA[<p>HWM - CT Self Regulating Hot-Water Maintenance Heat Trace Cable , Available in 16 W/m , 30 W/m ,240V &#38; 110V Hot Water Maintenance for Temperatures up to 140°F<br />
Heat Output Varies Along Pipe Length to Deliver Heat Where Needed<br />
Circuit Lengths up to 800 ft<br />
16 Awg Buss Wires<br />
Self-Regulating Conductive Core<br />
Fluoropolymer Jackets<br />
Wattages at 5 and 10 w/ft<br />
120 and 208-277 V Cable Available from Stock<br />
Third-party certifications: FM</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-5/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The HWM hot water temperature maintenance system utilizes self-regulating heat trace technology. The system, consisting of the self-regulating cable, connection kits and specialized electronic controls, provides commercial buildings with immediate hot water availability without expensive recirculation systems. It provides a simple, yet energy efficient approach by providing heat at the point where heat loss occurs. Due to the parallel construction of the self-regulating cable, it can be cut to any length, spliced, tee-branched and terminated on site. With this product, energy savings may be derived from multiple sources, such as lower supply line heat loss, eliminated return line heat loss, no pump operating costs and no supply water overheating costs. WARNING — A ground fault protection device is required by NEC to minimize the danger of fire if the heating cable is damaged or improperly installed. A minimum trip level of 30mA is recommended to minimize nuisance tripping.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-5/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Self Regulating Heat Trace Cables</title>
		<link>https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-6/</link>
		
		<dc:creator><![CDATA[thp]]></dc:creator>
		<pubDate>Fri, 01 Nov 2019 10:17:46 +0000</pubDate>
				<guid isPermaLink="false">https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-6/</guid>

					<description><![CDATA[<p>SRF-RG Self-Regulating Roof &#38; Gutter Cabe Roof and Gutter De-Icing<br />
Fast, Easy Installation<br />
Cut to Length<br />
UL Listed<br />
CSA Certified<br />
Approximate Size 3/8"W x 1/8"H<br />
Minimum Bend Radius 1-1/8"</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-6/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Chromalox SRF-RG self-regulating heating cable provides reliable freeze protection of roofs and gutters. Because SRF-RG is self-regulating, it automatically adjusts to the appropriate heat output as ambient conditions change, making it both energy efficient and cost effective. The protective waterproof outer jacket is suitable for wet applications in downspouts and roof drains. Likewise, it is easy to apply SRF-RG following the provided instruction sheets and utilizing the required accessory kits. It can be cut-tolength and overlapped. Simply trace the gutter or roof and energize the cable when precipitation is expected. From that point on, SRF-RG will rapidly increase its output when in contact with snow or ice, providing maximum melting power. When the roof and gutters are clear of snow and ice, the SRF-RG cable will regulate its output and save energy. WARNING — A ground fault protection device is required by NEC to minimize the danger of fire if the heating cable is damaged or improperly installed. A minimum trip level of 30mA is recommended to minimize nuisance tripping.</p>
<p>The post <a href="https://traceheatingproducts.co.uk/product/self-regulating-heat-trace-cables-6/">Self Regulating Heat Trace Cables</a> appeared first on <a href="https://traceheatingproducts.co.uk">THPUK</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
